Error Messages

Follow the corrective actions described below when the error messages are shown on the display:
Error Message
2TR-D1 No Input!
2TR-D2 Cascade Disabled
2TR-D2 No Input!
2TR-D3 No Input!
Automix Aborted!
Automix Disabled!
Automix REC Ready!
Automix Recording!
Automix Running!
Automix Updated!
Byte Count Error!
Can't assign 2TR-D1!
Can't assign 2TR-D2!
Can't select SLOT3!
Can't select SLOT4!
Can't select WORD CLOCK!
Cannot Copy Title!
Cannot Paste Title!
Check Sum Error!
Code Mismatch!
DIGITAL I/O Error!
Duplicate Grouping!
Correct digital signal is not input to 2TR-D1.
(C-R monitoring is not available.)
2TR-D2 cannot be routed to STEREO BUS.
(Incorrect word clock setting)
Correct digital signal is not input to 2TR-D2.
(C-R monitoring is not available.)
Correct digital signal is not input to 2TR-D3.
(C-R monitoring is not available.)
Automix data was aborted.
(You can undo the operation.)
Time code was input, but automix is disabled.
Ready for recording automix.
Recording automix now.
Automix is now running.
Automix has been updated.
(You can undo the operation.)
Byte count for the received bulk data is not correct.
2TR-D1 cannot be routed to line 17/18. (The signal at 2TR-D1 is not
syncing with the 02R, or 2TR-D1 has been selected in the C-R mon-
itor section.)
2TR-D2 cannot be routed to line 19/20. (The signal at 2TR-D2 is not
syncing with the 02R, or 2TR-D2 has been selected in the C-R mon-
itor section.)
SLOT3 cannot be selected for digital input.
(The I/O card is not in SLOT3.)
SLOT4 cannot be selected for digital input.
(The I/O card is not in SLOT4.)
Not available as a word clock source.
You cannot copy the title from the memory that has no data.
You cannot paste the title to the memory that has no data.
Check sum of the received bulk data is not correct.
Product code for the received bulk data is not correct.
Incoming signal from SLOT DIO is not syncing with the 02R. The
synchronization system has not been configured successfully. Or, if
the sync system has been configured, this message may still appear
if the clock sent from the MTR is unstable until the digital MTR enters
CHASE status. You can select whether this message will be shown or
not. (see "Preferences" on page 198 of the User's Guide )
You cannot duplicate the group.