K-7 Focus Setup
K-7-1
Focal Distance
Definition:
Serial Cmd:
Default:
Options:
K-7-2
Distance Units
Definition:
Serial Cmd:
Default:
Options:
For example, the following are valid configurations to set the Focal Distance to three distances:
Required Focal Distance
2 inch, or 50 mm
3 inch, or 76 mm
6 inch, or 152 mm
K-7-3
Focus Mode
Definition:
Serial Cmd:
Default:
Options:
K-7-4
No-Read Limit
Definition:
Serial Cmd:
Default:
Options:
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
Provides the focal distance adjustment for the camera.
Any value outside this range will be rejected.
If you attempt to set the Focal distance as the out of range value of your
model, the parameter will be left as-is.
<K525,focal distance,distance units,focus mode,no-read limit>
102
25 to 4,000 (mm)
100 to 4,000 (1/100 inch)
Defines the measurement unit value of the Focal Distance parameter.
<K525,focal distance,distance units,focus mode,no-read limit>
Millimeters
0 = Millimeters
1 = 1/100 inch
Distance Units = mm (0)
<K525,50,0>
<K525,76,0>
<K525,152,0>
This field set to 1 enables the autofocus mode to be enabled. The read
cycle must also be a Continuous Read mode or Continuous Read
Auto (Auto Photometry) mode. Autofocus mode does not apply to triggered
read cycles. If the value is set to 0, only the distance value is used.
<K525,focal distance,distance units,focus mode,no-read limit>
No-Read Autofocus
0 = User Value Only
1 = No-Read Autofocus
This is the number of no-reads that are encountered consecutively in a
Continuous Read mode to trigger an Autofocus pass.
<K525,focal distance,distance units,focus mode,no-read limit>
5
1 to 255
Appendices
Distance Units = 1/100 in. (1)
<K525,200,1>
<K525,300,1>
<K525,600,1>
K