Disabled
When Image Process Looping is set to Disabled, an image is captured for every database configura-
tion, whether or not any camera settings have been modified.
Enabled
When Image Process Looping is set to Enabled, the last captured image frame is re-processed with the new
IP and decode parameters. If camera settings have not been changed from the last capture event, and
when a database configuration is loaded to current, active settings, no new image is captured.
Note: An exception to this is the first database index: a new image is always captured when the first
database index is used. When a camera setting has been modified from one database setting to the
next, a new image is captured. For example, if all database entries contained the same camera setting
values but had different IP and decode parameters, an image frame would only be captured when the
first database configuration was used.
L-5-4
Image Dimensions
Definition:
Determines how the image dimension parameters will be implemented.
Serial Cmd: <K256,switch mode,frame count/time,image process looping,image dimensions>
Default:
0
Options:
0 = Window of Interest
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
1 = Region of Interest