Iso/Iec 29158 Symbol Quality Output - Omron MicroHAWK V320-F User Manual

Hide thumbs Also See for MicroHAWK V320-F:
Table of Contents

Advertisement

I-8
ISO/IEC 29158 Symbol Quality
Output
Symbol Quality Parameters for direct part marking specified by ISO/IEC 29158
Supported Symbologies:
• DataMatrix ECC200
Minimum Resolution: 6.0 Pixels Per Element
I-8-1
Overall
Definition:
Serial Cmd:
Default:
Options:
I-8-2
Cell Contrast
Definition:
Serial Cmd:
Default:
Options:
I-8-3
Cell Modulation
Definition:
Serial Cmd:
Default:
Options:
I-8-4
Fixed Pattern Damage
Definition:
Serial Cmd:
Default:
Options:
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
The overall grade is the minimum grade of all evaluated parameters,
noting minimum reflectance is not evaluated.
When enabled, the overall grade is attached to the symbol output data
as a value.
<K727, overall, cell contrast, cell modulation, fixed pattern damage,
axial non-uniformity, grid non-uniformity, unused ECC>
Disabled
0 = Disabled
Cell Contrast is calculated in accordance with the ISO 29158 specifica-
tion.
When enabled, the Cell Contrast is attached to the symbol output data
as a value.
<K727, overall, cell contrast, cell modulation, fixed pattern damage,
axial non-uniformity, grid non-uniformity, unused ECC>
Disabled
0 = Disabled
Cell Modulation is calculated in accordance with the ISO 29158 specifi-
cation. Note the difference in the calculation for Cell Modulation versus
Modulation in ISO 15415 eliminated the need for the parameter Reflec-
tance Margin which was added to ISO 15415.
When enabled, the Cell Modulation is attached to the symbol output
data as a value.
<K727, overall, cell contrast, cell modulation, fixed pattern damage,
axial non-uniformity, grid non-uniformity, unused ECC>
Disabled
0 = Disabled
Fixed Pattern Damage is calculated in accordance with the ISO 29158
specification.
When enabled, the Fixed Pattern Damage is attached to the symbol
output data as a value.
<K727, overall, cell contrast, cell modulation, fixed pattern damage,
axial non-uniformity, grid non-uniformity, unused ECC>
Disabled
0 = Disabled
1 = Enabled
1 = Enabled
1 = Enabled
1 = Enabled