Service Message - Omron MicroHAWK V320-F User Manual

Hide thumbs Also See for MicroHAWK V320-F:
Table of Contents

Advertisement

H-20 Service Message
When Service Message is enabled, a message of up to 10 ASCII characters is sent whenever the
system detects that the service timer's limit has been reached. The service timer is reset at power-on,
meaning that the service timer's limit is the amount of time since last reset. Service timer increments
can be set in seconds or minutes.
Serial Cmd:
Default:
Options:

Service Message

Serial Cmd:
Default:
Options:
Threshold
Serial Cmd:
Default:
Options:
Resolution
Serial Cmd:
Default:
Options:
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual
<K409,status,service message,threshold,resolution>
0
0 = Disabled
<K409,status,service message,threshold,resolution>
SERVICE
An ASCII string between 1 and 10 characters.
<K409,status,service message,threshold,resolution>
300 (5 minutes)
1 to 65535
<K409,status,service message,threshold,resolution>
Seconds
0 = Seconds
1 = Enabled
1 = Minutes
Appendices
H
H-45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Microhawk v330-fMicrohawk v420-fMicrohawk v430-f

Table of Contents