D-11 Preamble
D-11-1 Preamble Status
Usage:
Definition:
Serial Cmd:
Default:
Options:
D-11-2 Preamble Characters
Serial Cmd:
Default:
Options:
D-14
Useful for identifying and controlling incoming data. For example, defining
the preamble as a carriage return and a line feed causes each decoded
message to be displayed on its own line.
Defines a one to four character data string that can be added to the front of
the decoded data.
<K141,status,preamble character(s)>
Disabled
0 = Disabled
1 = Enabled (within any protocol)
<K141,status,preamble character(s)>
^M corresponds to: carriage return.
To enter control characters within a serial command, hold down the Ctrl
key while typing the desired character.
Example: <K141,1,CNTL-m> to enter the control character ^M.