Appendices
F-4-2
Leading Edge Trigger Filter
Usage:
Definition:
Serial Cmd:
Default:
Options:
F-4-3
Trailing Edge Trigger Filter
Usage:
Definition:
Serial Cmd:
Default:
Options:
F-8
Used to ignore spurious triggers when Trigger Mode is set to External
Edge or External Level.
To consider a change in state on the trigger input, the level must be stable
for the trigger filter duration. In an edge mode, the reader will trigger a read
cycle if the active state has been uninterrupted for the entire trigger filter
duration. In a level mode, the leading edge is filtered such that on an active
edge, the state must be held interrupted for the trigger filter duration before
a trigger will occur.
<K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
1
1 to 65535 (Trigger filter range: 32.0 µs to 2.10 seconds)
Used to ignore spurious triggers when Trigger Mode is set to External
Edge or External Level.
To consider a change in state on the trigger input, the level must be stable
for the trigger filter duration. In an edge mode, the reader will trigger a read
cycle if the active state has been uninterrupted for the entire trigger filter
duration. In a level mode, the trailing edge is filtered such that on the falling
edge, the state must be held for the trigger filter duration before the trigger
will be deemed inactive.
<K200,trigger mode,leading edge trigger filter,trailing edge trigger filter>
1
1 to 65535 (Trigger filter range: 32.0 µs to 2.10 seconds)
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual