2-2-8
Configure Read Cycle Settings
The Cycle section of the Setup view allows you to modify the trigger, determine the number of symbols
for the reader to expect, and set Read Cycle Timeout. A dropdown menu of various Cycle types
provides a variety of options, each with configurable parameters.
Presentation
This mode uses Continuous Read Auto along with Continuous Capture Mode and a Timeout at
End of Read Cycle. Green Flash Mode is set to Static Presentation and the Green Flash Duration
is set to 1 second.
Continuous
This mode allows you to set the Read Cycle Timeout and the expected Number of Symbols from 1
to 100.
Triggered
This mode sets the read cycle to Serial Data and Edge, End of Read Cycle is set to Timeout or
New Trigger, and Capture Mode is set to Rapid Capture with 1 capture. You can adjust the Serial
Trigger, Trigger Delay, Timeout, and Number of Symbols.
Start / Stop
This mode uses External Level with a Read Cycle Timeout and Continuous Capture, allowing you
to set Leading Edge and Trailing Edge as well as the Serial Trigger and the Start and Stop
characters.
Serial Trigger (Non-Delimited) Off
When Serial Trigger is set to Off, the start and stop characters are set to NULL, meaning that the
trigger is disabled.
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual