Appendices
D-7-4
IP Address Mode
Determines how the reader's IP address will be defined.
Static
In Static Mode, the reader uses the user-defined IP address. This is the default state for the
MicroHAWK V430-F.
DHCP
In DHCP Mode, the reader automatically acquires the IP address, Subnet, and Gateway addresses
from a DHCP or BOOTP server.
D-7-5
TCP Port 1
One of two TCP ports for Ethernet communication with the reader. The default setting is 2001.
D-7-6
TCP Port 2
One of two TCP ports for Ethernet communication with the reader. The default setting is 2003.
Changes to this parameter are saved to NOVRAM and are set to default on power on.
A Reset <A> is required for settings to take effect.
• Important: Once this setting is Disabled, you will only be able to connect to the reader if you know the IP
address and enter it in the IP Address field of the Ethernet TCP/IP connect dialog.
When enabled, Search and Configure Mode will find the reader and settings can be changed.
Timed Window
When Timed Window is selected, Search and Configure Mode will find the reader and settings can be
changed, but only 60 seconds from the last reset. After 60 seconds, Search and Configure Mode will be
disabled.
D-10
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual