Illumination Brightness - Omron MicroHAWK V320-F User Manual

Hide thumbs Also See for MicroHAWK V320-F:
Table of Contents

Advertisement

Appendices
K-8 Illumination Brightness
Definition:
Serial Cmd:
Default:
Options:
Constant
When set to Constant, the illumination brightness is the same power level as the High setting.
However, the LEDs will always be on during a read cycle and will only be off between read cycles. This
cuts down on perceptible LED flashing.
Extreme
When set to Extreme, illumination brightness enters Power Strobe mode. In this mode, illumination
is extremely intense, and can only be activated for a maximum of 1 ms.
K-8-1
Light Source
Definition:
Serial Cmd:
Default:
Options:
External Strobe
For Configurable Output 3 (K812), Output On, Use as External Illumination Strobe to function,
Light Source must be set to External Strobe.
K-10
This feature allows you to adjust the brightness of the illumination LEDs.
Since the reader has control over the brightness of the illumination, it can
provide consistent brightness output between readers through a factory
calibration operation. Each of the brightness settings is calibrated to provide
the same level of intensity for each reader.
<K536,brightness,light source,fixed light on time,fixed light on delay
time>
High
0 = Off
1 = Low
2 = Medium
3 = High
4 = Constant
5 = Extreme
The setting allows the user to change the illumination light source.
<K536,brightness,light source,fixed light on time,fixed light on delay time>
Outer LED Only
0 = External Strobe
1 = Inner White LED Only
2 = Inner Red LED Only
3 = Outer LED Only
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Microhawk v330-fMicrohawk v420-fMicrohawk v430-f

Table of Contents