Omron MicroHAWK V320-F User Manual page 499

Hide thumbs Also See for MicroHAWK V320-F:
Table of Contents

Advertisement

Appendices
Is it possible to
function the
autofocus while
reading?
What is the number
of the maximum
characters for Match
String Database?
How to change
Match String
externally?
How to enable the
External Trigger
rather than
Continuous Read?
How can I confirm
the OK/NG Read
result over
EtherNet/IP?
R-8
The autofocus while reading can be enabled when the Read Cycle is set to Continuous Read or
Continuous Read Auto.
Since the autofocus adjustment needs several seconds, use the Configuration Database function
when switching the mount distances that are predetermined.
Related Q&A: Can serial commands calibrate brightness or focus?
It is 3,000 characters.
It is divided by the number of registrations, so it varies depending on the number of registrations.
When the number of registrations is one, it can register up to 3,000 characters.
When the number of registrations is ten, each registration can register up to 300 characters.
Related Q&A: What is the number of the maximum readable characters?
Use <K231> command.
Command format: <K231, index, master symbol data>
Example:
When setting ABC to the first Match String Database:
<K231, 1, ABC>
Set the Trigger Mode except for Continuous Read. Refer to the following instruction.
Select Gear icon - Advanced - Read Cycle - Trigger - Mode - External Edge or Serial Data and
Edge.
The method differs according to the selected input assembly.
• When using a Small (100) assembly;
First determine whether the Output String (DECODE DATA STRING) is NOREAD (default).
• When using a Big (101) assembly;
There is a way to verify the External Output Status OUTPUT bit.
Please note that the External Output Status is dependent on the Output condition setting for the
Parallel I/O OUTPUT signal. The default setting is ON when there is a Read Fail.
• When an assembly after MXL/SLC (102) is selected;
You can verify the Read Cycle Pass, Read Cycle Fail bit status in Device Status. The Read
Cycle Pass, Read Cycle Fail bit is OFF during a READ cycle and is updated when Data Is Ready
is ON.
MicroHAWK V320-F / V330-F / V420-F / V430-F Barcode Reader User Manual