If the system produces the T6DH sensor error hose
alarm or the T6DT sensor error TCM alarm, use
Manual Hose Mode until the hose RTD cable or FTS
temperature sensor can be repaired.
NOTE: Do not use the Manual Hose Mode for
NOTE:
NOTE:
extended periods of time. The system performs best
when the hose has a valid RTD and can operate in
temperature control mode. If a hose RTD breaks, the
first priority is to fix the RTD. Manual Hose Mode can
help finish a job while waiting for repair parts.
Enable Manual
Manual Hose
Hose Mode
Enable
Enable
Manual
Hose
1. Disconnect the hose RTD sensor from the TCM.
2. Enter Setup Mode and navigate to System
Screen 2.
333023M
Mode
Mode
Mode
Mode
3. Select Enable Manual Hose Mode.
Note
When manual hose mode is enabled, the
manual hose mode advisory EVCH-V
will appear.
4. Enter Run Mode and navigate to the Target
screen. Use the up and down arrows to set the
desired hose current.
Hose Current
Current Settings
Settings Hose
Hose
Hose
Current
Settings
Default
Maximum

Manual Hose Mode

Hose Current
Current
Hose
Current
20A
37A
51