Purge Air Procedure - Graco Reactor 2 E-30 Operation

Proportioning systems
Hide thumbs Also See for Reactor 2 E-30:
Table of Contents

Advertisement

Purge Air
Air Procedure
Procedure
Purge
Purge
Air
Procedure
NOTE:
NOTE: Perform this procedure any time air is
NOTE:
introduced into the system.
1. Relieve pressure.
Pressure Relief Procedure, page
2. Install a recirculation kit or install bleed lines
between the outlet manifold recirculation fitting
and a waste container.
NOTICE
NOTICE
NOTICE
To prevent equipment damage, do not circulate
fluid containing a blowing agent without
consulting with your material supplier regarding
fluid temperature limits.
3. Press the proportioner stop button
off the motor.
4. To relieve air pressure from the feed pumps,
disconnect the air supply lines (G) from the feed
pumps (K).
333023M
See
57.
to turn
5. Set the PRESSURE RELIEF/SPRAY valves
(SA, SB) to PRESSURE RELIEF/CIRCULATION
.
SA
6. Adjust the pressure in the feed pump air supply
lines to 100 psi.
7. To pressurize the feed pumps, connect the air
supply lines (G) to the feed pumps (K).
8. Press the Jog mode button
mode. Use the arrow keys
speed to J20.
9. Press the jog mode start button
motor. Run 1 gallon (3.8 L) of material through
the system.
10. Set the PRESSURE RELIEF/SPRAY valves (SA,
SB) to SPRAY
SA

Purge Air Procedure

GB
GA
SB
to enter Jog
to set the jog
to start the
.
GA
GB
SB
55