Shutdown - Graco Reactor 2 E-30 Operation

Proportioning systems
Hide thumbs Also See for Reactor 2 E-30:
Table of Contents

Advertisement

Shutdown

Shutdown
Shutdown
NOTICE
NOTICE
NOTICE
Proper system setup, startup, and shutdown
procedures are critical to electrical equipment
reliability. The following procedures ensure steady
voltage. Failure to follow these procedures will
cause voltage fluctuations that can damage
electrical equipment and void the warranty.
1. Press
to stop the pumps.
2. Turn off all heat zones.
3. Relieve pressure.
Pressure Relief Procedure, page
4. Press
to park the Component A Pump. The
park operation is complete when green dot goes
out. Verify the park operation is complete before
moving to next step.
5. Press
to deactivate the system.
333023M
See
57.
6. Turn off the air compressor, air dryer, and
breathing air.
7. Turn main power switch OFF.
To prevent electric shock do not remove any
shrouds or open the electrical enclosure door.
8. Close all fluid supply valves.
Shutdown
53