Run Mode
Diagnostic
Diagnostic
Diagnostic
Use this screen to view information for all system
components.
The following information is displayed:
Temperature
Temperature
Temperature
• A Chemical
• B Chemical
• Hose Chemical
• TCM PCB — temperature control module
temperature
Amps
Amps
Amps
• A Current
(0–25 A for 10kW heater, 0–38 A for
15 kW heater)
• B Current
(0–25 A for 10kW heater, 0–38 A for
15 kW heater)
• Hose Current
(0–45 A typical)
Volts
Volts
Volts
• MCM Bus
— displays the voltage supplied to the
motor controller, which is the DC voltage that has
been converted from the AC voltage supplied to
the system (275–400 V typical full range)
• A Voltage – Voltage supplied to A heater (195–240
V typical)
• B Voltage – Voltage supplied to B heater (195–240
V typical)
• Hose Voltage (90V)
Pressure
Pressure
Pressure
• Pressure A — chemical
• Pressure B — chemical
Cycles
Cycles
Cycles
• CPM — cycles per minute
• Total Cycles — lifetime cycles
42
Note
Maximum values based on maximum input
voltage. Values will lower with lower input
voltage.
Job
Job Data
Job
Data
Data
Use this screen to enter a job name or number.
Recipes
Recipes
Recipes
Use this screen to select an enabled recipe. Use the
up and down arrows to highlight a recipe and press
to load. The currently loaded recipe is outlined
by a green box.
Note
This screen will not display if there are not
any enabled recipes. To enable or disable
recipes, see
Recipes Setup Screen, page
35.
333023M