Graco Reactor 2 E-30 Operation page 45

Proportioning systems
Hide thumbs Also See for Reactor 2 E-30:
Table of Contents

Advertisement

9. Switch on the air compressor, air dryer, and
breathing air, if included.
For first
first startup
startup of of of new
new system,
10. For
For
first
startup
new
feed
feed
feed pumps.
pumps.
pumps.
Setup steps are complete.
a. Check that all Setup
Setup
See
Setup, page
b. If an agitator is used, open the agitator's air
inlet valve.
c. If you need to circulate fluid through the
system to preheat the drum supply, see
Circulation Through Reactor, page
If you need to circulate material through
the heat hose to the gun manifold, see
Circulation Through Gun Manifold, page
d. Turn both PRESSURE RELIEF/SPRAY
valves (SA, SB) to SPRAY
SA
333023M
system, load
load fluid
fluid with
with
system,
load
fluid
with
27.
47.
.
GA
GB
SB
e. Open fluid inlet valves (FV). Check for leaks.
Cross-contamination can result in cured
material in fluid lines which could cause
serious injury or damage equipment. To
prevent cross-contamination:
• Never
Never interchange component A and
Never
component B wetted parts.
• Never use solvent on one side if it has
been contaminated from the other side.
48.
• Always provide two grounded waste
containers to keep component A and
component B fluids separate.
f.
Hold gun fluid manifold over two grounded
waste containers. Open fluid valves A and B
until clean, air-free fluid comes from valves.
Close valves.
The Fusion AP gun manifold is shown.
Startup
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reactor 2 e-xp2Reactor 2 e-30 eliteReactor 2 e-xp2 elite272010272011272110 ... Show all