System 1 1 1
System
System
Use this screen to enable pressure imbalance alarms
and deviations, set pressure imbalance values,
enable low chemical alarm, and enable inlet sensors.
Select accessories using this screen. If the flow
meter accessory is installed, use this screen to:
• Enable ratio errors.
• Set the ratio alarm percentage.
• Enable Reactor Smart Control.
333023M
System 2 2 2
System
System
Use this screen to enable Manual Hose Mode,
Integrated Mode, and the diagnostic screen. This
screen can also be used to set the primary heater
size, set the maximum and minimum drum volume,
and enable the drum alarms.
Manual Hose Mode disables the hose temperature
RTD sensor so the system can operate if the
sensors were to malfunction. Manual Hose Mode
is only available when the hose temperature RTD
sensor is disconnected. Integrated Mode allows the
Reactor 2 to control an Integrated PowerStation, if
the Integrated PowerStation is installed. If the flow
meter accessory is installed, use this screen to set
the k-factors. K-factors are printed on the flow meter
serial number labels.
Recipes
Recipes
Recipes
Use this screen to add recipes, view saved recipes,
and enable or disable saved recipes. Enabled
recipes can be selected at the Home Run Screen. 24
recipes can displayed on the three recipe screens.
System 1
35