Connect the Air Supply Line
Connect the Air Supply Line
Connect the Air Supply Line
Connect the Air Supply Line
NOTE:
To ensure the maximum pump performance, be
sure that all the accessories used are properly sized to
meet your system requirements. Use only genuine
Graco parts and accessories.
In the air line, install an air filter to remove harmful dirt
and moisture from the compressed air supply. Install an
air line lubricator downstream from the air filter, the sup-
plied air regulator, and the bleed-type master air valve.
The lubricator provides automatic lubrication to the air
motor.
The supplied bleed-type master air valve is required in
your system to relieve the air trapped between the
valve and the pump after the pump is shut off. Trapped
air can cause the pump to cycle unexpectedly, which
can result in serious injury.
Connect a 1/2" minimum ID grounded air supply hose to
the 1/2 npt(f) port of the air regulator. Open the bleed-
type master air valve and set the air regulator to the
desired pressure, using the pressure gauge.
Connect the Solvent Supply Line
Connect the Solvent Supply Line
Connect the Solvent Supply Line
Connect the Solvent Supply Line
Remove the coupling from the solvent inlet on the mix
manifold and install a grounded fluid supply from the
solvent pump.
10
WARNING
Ground the System
Ground the System
Ground the System
Ground the System
Fire and Explosion Hazard
Before operating the system, ground it as explained
below. Also read the Fire or Explosion Hazard section
on page 7.
Ground all of this equipment:
•
Pump:
Use a ground wire and clamp as shown in
Figure 3. Loosen the grounding lug locknut and
washer (X). Insert one end of a 12 ga. (1.5 mm²)
minimum ground wire (Y) into the slot in lug (Z) and
tighten the locknut securely. Connect the other end
of the wire to a true earth ground. Order part num-
ber 222011 Grounding Clamp and Wire.
•
Fluid hoses:
Use only grounded fluid hoses.
•
Air hoses:
Use only grounded air hoses.
•
Spray Guns:
Obtain grounding through connection
to a properly grounded fluid hose and pump.
•
Fluid supply container:
•
Air compressor:
Follow your local code.
•
To maintain grounding continuity when flushing or
relieving pressure:
gun firmly to the side of a grounded metal pail, then
trigger the gun.
•
All solvent pails used when flushing:
local code. Use only metal pails, which are conduc-
tive, placed on a grounded surface. Do not place
the pail on a non-conductive surface, such as paper
or cardboard, which interrupts the grounding conti-
nuity.
X
W
Z
Figure 3 - Pump Grounding Lug
Installation
WARNING
Follow your local code.
Hold a metal part of the spray
Follow your
Y
309239 Instructions - Parts List