Configuration / parameterization
5.1 Configuring
5.1.1

Configuring with STEP 7

Introduction
The M200D motor starter is listed in the hardware catalog of HW Config after you start
STEP 7.
Requirements
● STEP 7 Version 5.4 + SP5 or higher
● Current software (STEP 7 HSP) for M200D PROFIBUS or M200D PROFINET
● PROFINET IO: Assigning a name to the IO device (see Assigning IO device names
(PROFINET IO) (Page 123))
Updating software (STEP 7 HSP)
Proceed as follows to update your software over the Internet:
1. Open the STEP 7 software HW Config.
2. Select "Options" > "Install HW Updates".
3. In the screen form that then appears, activate the option "Download from the Internet".
(Make sure there is an active connection to the Internet.)
4. Click on the required updates in the table and then on "Select all".
5. Click on "Execute".
6. The updates are installed.
Configuration and parameterizing
1. Start the SIMATIC Manager.
2. Create a new project.
3. Configure the M200D motor starter with HW Config.
4. Double-click on the M200D motor starter in the configuration table and set the
parameters.
5. Save the configuration, or download it to the DP master/IO controller.
Reference
For further information, refer to the STEP 7 Online Help.
120
M200D PROFIBUS/PROFINET
Manual, 08/2014, A5E01577426A/RS-AA/004