Mounting / connection
4.2 Connection
4.2.7

Inputs / outputs

Assignment of the digital inputs and outputs (M12 socket)
4.2.7.1
Digital inputs IN1 to IN4
The motor starters are equipped with four digital inputs, which you can connect directly to
sensors (PNP) (2 and 3-wire system).
Connectors (M12, 5-pin, A-coded) are used for this purpose. The motor starter is equipped
with a range of sockets.
Note
Short-circuit hazard
Do not use an external power supply since this can result in a short-circuit.
Pin assignment
The following diagrams show examples of circuits (2 and 3-wire system):
Note
The supply voltage for the digital inputs is short-circuit proof. The current is limited to max.
200 mA. If a short-circuit or overload situation occurs in the sensor supply, the switching
element (motor) and brake output are shut down and a group fault is output. You must
acknowledge this fault with a trip reset.
110
Pin
1
2
3
4
5
2-wire system
Input assignment
+ 24 V DC24V-NS (+)
N/C
0 V DC24V-NS (-)
DIx
FE
3-wire system
Manual, 08/2014, A5E01577426A/RS-AA/004
Output assignment
N/C
N/C
0 V DC24V-S (-)
OUTx
FE