Table 6: Failure scenarios and repair actions (continued)
Problem
"Not enough memory in
RAM"
"Not enough memory in
NVRAM"
"File already Exists in other
Bank"
"TFTP - General failure"
"Can't start upload operation.
Wrong operation parameters
or other operation already in
progress, please try again"

Upgrading considerations

Configuration files, such as upgrade script and setting files, are copied to the phone
configuration banks in NVRAM, while phone images are stored in RAM
Note:
Image files are cleared if you reset the gateway.
Note:
Phone image banks are stored in the same TFTP directory. Therefore, you cannot copy
the same file name to more then one bank. Copying a file to a bank containing a file with
the same file name causes the old file to be overwritten by the new one.
File names for IP phone image files and script files are limited to 32 characters
Possible cause
The remote file is larger than
the available RAM.
The remote file is larger than
the available NVRAM.
You tried to download the
same file to more than one
bank.
File name or path incorrect
You are trying to upload a file
from an empty bank.
Upgrading considerations
Action
Free more space in the
RAM using the erase
phone-script or
erase phone-image
command.
Free space in the NVRAM
using the erase
phone-script
command.
None. You cannot load
two files with the same file
name to more than one
bank.
Check the file name and
path.
Upload from a different
bank.
Download a file to the
bank.
2 of 2