Inverter Capacity Display
The voltage class and maximum applicable motor capacity (whose parameters stored in
the digital operator are read out) is displayed.
[Example] Display the voltage class and maximum applicable motor capacity
for the inverter whose parameters stored in EEPROM inside the digital
operator.
• Enable the setting of the
parameters n001 to n179.
• Execute Inverter Capacity
Display (vA) by parameter copy
function selection (n176)
The following shows the explanation of Inverter Capacity Display
Voltage class
2
Three-phase 200V
b
Single-phase 200V
4
Three-phase 400V
122
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Explanation
• Press DSPL to light [PRGM].
• Press ENTER to display the set
(Can be a different parameter No.)
value.
( Lit )
• Change the set value to 4 by
(Can be a different set value.)
pressing
or
key.
(Blinks)
• Press ENTER.
(Lit for one second.)
(The parameter is
displayed)
• Change the parameter No. to
n176 by pressing
or
key.
• Press ENTER to display the set
(Lit)
value.
(Lit)
• Change the set value to vA by
(Lit) (For20P7)*
pressing
or
key.
• Press ENTER.
(The parameter No. is
• Press DSPL or ENTER.
displayed.)
Max. applicable motor capacity
200V class
0.1
0.1kW
0.2
0.25kW
0.4
0.55kW
0.7
1.1kW
1.5
1.5kW
2.2
2.2kW
3.0
4.0
4.0kW
Operator display
400V class
-
0.37kW
0.55kW
1.1kW
1.5kW
2.2kW
-
3.0kW
4.0kW