• 200V class single-phase
No.
Name
Inverter capacity
n036 Motor rated current
Torque
n105
compensation iron
loss
n106 Motor rated slip
Motor resistance for
n107
one phase*
Motor leak
n108
inductance
Motor no-load
n110
current
• 400V class 3-phase
No.
Name
Inverter capacity
n036 Motor rated current
Torque
n105
compensation iron
loss
n106 Motor rated slip
Motor resistance for
n107
one phase*
Motor leak
n108
inductance
Motor no-load
n110
current
* Values of motor line-to-line resistance are set to half of the standard value.
= Values between V/f mode and Vector control mode.
166
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Unit
Factory setting
kW 0.1kW 0.25kW 0.55kW 1.1kW 1.5kW 2.2kW – 3.7kW 5.5kW 7.5kW
A
0.6
1.1
1.9
3.3
6.2
8.5
W
1.7
3.4
4.2
6.5
11.1
11.8
Hz
2.5
2.6
2.9
2.5
2.6
2.9
17.99
10.28
4.573
2.575 1.233
0.8
MH 110.4
56.08
42.21
19.07
13.4
9.81
%
72
73
62
55
45
35
Unit
Factory setting
kW
– 0.37kW 0.55kW 1.1kW 1.5kW 2.2kW 3.0kW 3.7kW 5.5kW 7.5kW
A
0.6
1.0
1.6
3.1
4.2
W
3.4
4.0
6.1
11.0
11.7
Hz
2.5
2.7
2.6
2.5
3.0
41.97
19.08
11.22 5.044 3.244 1.514 1.514 0.797 0.443
MH
224.3
168.8
80.76 53.25 40.03 24.84 24.84 16.87 10.59
%
73
63
52
45
35
14.1
9.8
13.3
19
28.8
43.9
3.3
1.5
1.3
0.385 0.797 0.443
6.34
16.87 10.59
32
26
30
7.0
7.0
9.8
13.3
19.3
19.3
28.8
43.9
3.2
3.2
1.5
1.3
33
33
26
30