6. PROGRAMMING FEATURES

Factory settings of the parameters are shown as

• Parameter Set-up and Initialization

Parameter selection/initialization (n001)
The following table describes the data which can be set or read when n001 is set.
Unused parameters among n001 to n179 are not displayed.
n001 Setting
Parameter that can be set
0
n001
1
n001 to n049*
2
n001 to n079*
3
n001 to n119*
4
n001 to n179*
5
Not used
6
Fault history cleared
8,9,12,13
Not used
10
Initialize
11
Initialize (3-wire sequence)=
* Excluding setting disabled parameters.
Refer to page 70.
=
"
" appears on the LED display for one second and the set data returns to
NOTE
its initial values in the following cases:
(1) The set values of input terminal function selection 1 to 7 (n050 to n056) are the
same.
(2) The following conditions are not satisfied in the V/f pattern setting:
Max. output frequency (n011) > Max. voltage output frequency (n013)
> Mid. output frequency (n014)
> Min. output frequency (n016)
For details, refer to "Adjusting torque according to application" (V/f pattern set-
ting) on page 38.
(3) If the following conditions are not satisfied in the Jump frequency setting:
Jump frequency 3 (n085)< Jump frequency 2 (n084)
(4) If Frequency reference lower limit (n034) > Frequency reference upper limit
(n033)
(5) If motor rated current (n036) > 150% of inverter rated current
(6) When n018 = 0 and n019 ~ n022 is set to a value greater than 600.0 sec, parameter
n018 will automatically be set to 1.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
in the tables.
Parameter that can be referred
n001 to n179
n001 to n049
n001 to n079
n001 to n119
n001 to n179
< Jump frequency 1 (n083)