Adjusting Frequency Reference Using Pulse Train Inputs

The frequency reference can be adjusted when b1-01 (Reference Selection) is set to 4 (Pulse Train Input). Set
the pulse frequency in constant H6-02 to 100% reference, and then adjust the gain and bias accordingly using
H6-03 and H6-04.
Related Constants
Name
Con-
stant
Display
Number
Pulse train
0: Frequency reference
input function
H6-01
1: PID feedback value
selection
2: PID target value
脉冲输入选择
Pulse train
Set the number of pulses in hertz,
input scaling
H6-02
taking the reference to be 100%.
脉冲输入比例
Pulse train
Set the input gain level as a per-
input gain
H6-03
cent when the pulse train set in
H6-02 is input.
脉冲输入增益
Pulse train
Set the input bias when the pulse
input bias
H6-04
train is 0.
脉冲输入偏置
Pulse train
input filter time Set the pulse train input primary
H6-05
delay filter time constant in sec-
脉冲输入滤波时
onds.
The following diagram shows the method for adjusting the frequency reference using pulse inputs.
RP
Cycle
measurement
Pulse
Fig 6.31 Frequency Reference Adjustments Using Pulse Train Inputs
Setting
Factory
Description
Range
0 to 2
1000
to
32000
0.0 to
1000.0
-100.0
to
100.0
0.00 to
2.00
Gain and bias
Filter
H6-03
1
1+sT
H6-04
0
100
H6-05
Scaling using H6-02
Adjusting Frequency References
Control Methods
Change
Open
during
V/f
Loop
Setting
Opera-
V/f
with
Vector
tion
PG
1
0
No
A
A
A
1440
Yes
A
A
A
Hz
100.0
Yes
A
A
A
%
0.0%
Yes
A
A
A
0.10
Yes
A
A
A
s
=0
=1
=2
H6-01
MEMO
Open
BUS
Flux
Loop
Regis-
Vec-
Vector
ter
tor
2
A
A
42CH
A
A
42DH
A
A
42EH
A
A
42FH
A
A
430H
Master speed
frequency
PID feedback
PID target value
33
6-

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents