Using frequency meter or ammeter (n066)
Selects the function to be monitored at analog output terminals AM-AC.
Setting
0
1
2
3
4
5
Output voltage reference
In initial setting, analog voltage of approx. 10V is output when output frequency
(output current) is 100%.
Calibrating frequency meter or ammeter (n067)
Used to adjust analog output gain.
Set the analog output voltage at 100% of output frequency (output current). Frequency
meter displays 0 to 60Hz at 0 to 3V.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Description
Output frequency
Output current
Main circuit DC voltage
Torque monitor
Output power
×
10V n067 Setting
3V
=
0.30
Output frequency becomes
100% at this value
65