Motor Modules in booksize C/D-type format
3.2 Motor Modules with internal air cooling
Temperature sensor connection
Danger to life due to electric shock in the event of voltage flashovers at the temperature
sensor
Voltage flashovers in the signal electronics can occur in motors without protective
separation of the temperature sensors.
• Use temperature sensors that comply with the specifications relating to protective
• If protective separation cannot be guaranteed (with linear motors or third-party motors,
NOTICE
Damage to motor in the event of incorrectly connected KTY temperature sensor
If a KTY temperature sensor is connected with incorrect polarity, it is not possible to detect
when the motor overheats. Overheating can cause damage to the motor.
• Connect the KTY temperature sensor with the correct polarity.
Note
The temperature sensor input is not needed if the motors feature an integrated DRIVE-CLiQ
interface or if temperature values are detected by means of a different module (SMC, SME,
TM).
3.2.2.4

X200-X203 DRIVE-CLiQ interface

Table 3- 3
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Additional blanking covers (50 units): Article number 6SL3066-4CA00-0AA0
48
WARNING
separation.
for example), use a Sensor Module External (SME120 or SME125) or the TM120
Terminal Module.
X200-X202: DRIVE-CLiQ interfaces for Single Motor Modules
X200-X203: DRIVE-CLiQ interfaces for Double Motor Modules
Pin
1
2
3
4
5
6
7
8
A
B
Name
TXP
TXN
RXP
Reserved, do not use
Reserved, do not use
RXN
Reserved, do not use
Reserved, do not use
+ (24 V)
M (0 V)
Technical data
Transmit data +
Transmit data -
Receive data +
Receive data -
Power supply
Electronics ground