Operation
7.8

Data storage via serial RS232-interface

For better prevention from loss of data, a data backup procedure is available for the system
configuration and the parameter sets. This is made via the RS232-interface (not in B- versions).
The secured data can be transferred to spare units in case of exchange after a failure.
The data backup is accomplished with the RPP software available from ROLAND.
The data backup procedure can be selected in the menu configuration. The following menu is
displayed during the data backup.
Parameter backup
active
Fig. 101: Status of data backup
7.9

Firmware update

Roland systems are constantly enhanced. In order to use new functions, firmware update is
required.
For performing such an update, the Double Sheet Detector must be connected to the RS232-
interface of the computer via the supplied cable. In the configuration mode the firmware update
must be selected, then the following messages are alternatingly displayed:
FIRMWARE UPDATE
start pressing key
Firmware update
arrow key UP + ENTER
Fig. 102: Messages for activating firmware update
The firmware update is activated by simultaneously pressing the keys arrow  and ENTER
for 5 seconds:
ROLAND R1000 BUS
- FIRMWARE UPDATE
- CONNECT RS232
- PRESS ENTER TO EXIT
Fig. 103: Start firmware update
The update will then be executed via the "Phytec" Flash Tool. This tool can be found on the
enclosed CD.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
124
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
Manual
B0048191 / Rev. 1.5