Faults Fieldbus Interface; Other Faults - Roland R1000 Series Manual

Double sheet detector with integrated fieldbus interface
Hide thumbs Also See for R1000 Series:
Table of Contents

Advertisement

Maintenance
9.11

Faults fieldbus interface

No.
Cause
80
The installed fieldbus coupler is defective.
82
The fieldbus function is not possible, for a parallel
PLC function is active, e.g. "Measurement start" via
the parallel PLC inputs and in addition
"Measurement start" via the fieldbus.
The fieldbus function is not possible, for another
83
field bus function is active at the same time, e.g.
"Measurement start" and "Program switching".
84
The fieldbus function is not possible, for the
measuring mode is set to "Demo".
85
The fieldbus function is not possible, for the menu
(keyboard operation) is operational.
86
The activated fieldbus function is not possible or
disabled in the system.
88
The program number activated in the menu program
selection is > 255.
91
The field bus function cannot be executed, for the
parameter channel is active.
92
The parameter channel is wrongly served.
94-98
Internal timing problem with bus module.
99
Bus module is defective.
9.12

Other faults

No.
Cause
> 100
An error has occurred which cannot be
unequivocally identified to one of the above error
codes.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
134
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
Manual
Remedy
Switch unit off and on, if the fault reappears then the
equipment has to be returned.
Avoid simultaneous operation.
Implement only one function.
Configure the parameter "measurement operation"
to "external continuous measurement" or "external single
measurement".
Terminate the operation via the keyboard and with the
"Menu" key return the unit to its basic mode.
If the function is required, then it should be activated
under "systems configuration".
Select a valid program number.
Close parameter channel.
Remedy
Contact Roland Electronic Service Department.