Electrical installation
4.4

Automatic tool changer

The Roland sensors can be used within an ATC concept (Automatic tool change).
The only requirements we have established are:
Every sensor signal must have its own contact.
The contacts must be low resistive (only gold contacts!).
The contacts must be suited for peak currents of 2 ampere.
The shielding of the cable must not be interrupted and therefore have its own contact.
The contacts must be protected from contamination.
Do not route the cable together with other cables leading high currents.
Die metallic parts of the tooling have to be grounded.
It is not allowed to open the connector during the measuring operation.
After each tool change it is required to perform a zero set command.
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
50
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
Attention
Incorrect wiring may destroy the control unit or the sensor.
Manual
B0048191 / Rev. 1.5