6.5

External I/O control

The system is normally controlled via the process channel. The exception is the signal
"Measurement start", which, for fast procedures, can also be controlled via the optocoupler inputs
(IN). A mixed operation is also possible. The control cannot, however, be made simultaneously by
both signal sources.
The "Measurement start" signals can be initiated via the process channel or the opto couplers.
Simultaneous initiation is not possible. That means that the initiation of measurement start is not
accepted by opto couplers, if measurement start of the process channel is active or not processed.
The same applies to the other way.
Signal
IN0
IN1
IN2
The "Measurement start" inputs are linked in different combinations via AND. The following
configuration can be selected in the control unit:
IN0
IN0 and IN1
IN0 and IN1 and IN2
In addition the signals 0-, 1-, 2-sheet, ENABLE and warning are available for further processing via
optocoupler (OUT).
Signal
Meaning
OUT0
Output 0-sheet
OUT1
Output 1-sheet
OUT2
Output 2-sheet
OUT3
Output ENABLE 4th Optocoupler output
OUT4
Warning
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
with integrated fieldbus interface
optocoupler inputs
Meaning
Measurement start input 1
Measurement start input 2
Measurement start input 3
optocoupler ouputs
Notes
1st Optocoupler output
standard 0 V active (selection in the control unit configuration)
2nd Optocoupler output
standard 0 V active (selection in the control unit configuration)
3rd Optocoupler output
standard 0 V active (selection in the control unit configuration)
standard 24 V active (cannot be selected for safety reasons)
5th Optocoupler output
standard 0 V active (cannot be selected for safety reasons)
Manual
Notes
Optocoupler input 1
Optocoupler input 2
Optocoupler input 3
Communication with the PLC
24 V active
24 V active
24 V active