7.2
Troubleshooting
7.2.1 Computer and Heating Problems
Problem
No Display on
Computer.
M2007 displays
GET MGR.
Fryer does not heat.
Probable Causes
A. Computer not turned on.
B. No power to the fryer.
C. Computer has failed.
D. Damaged computer wiring
harness.
E. Power supply component or
interface board has failed.
A filter error has occurred due to
dirty or clogged filter pad or paper,
clogged filter pumps, filter pump
thermal overload, or an actuator
problem and shut the computer off.
A. Drain valve is open.
B. Computer has failed.
Corrective Action
A. Press the ON/OFF switch to turn
the computer on.
B. This fryer has two cords: a
computer power cord and a main
power cord.
cord is not plugged in, the
computer
Verify computer power cord is
plugged in and that circuit
breaker is not tripped.
C. Call your FASC.
D. Call your FASC
E. If any component in the power
supply system (including the
transformer and interface board)
fail, power will not be supplied
to the computer and it will not
function.
component has failed is beyond
the
troubleshooting.
FASC.
Follow instructions on page 5-4
through 5-7 to clear the GET
MGR error. See also Filtration
Problems section page 7-6. If
problem persists, contact your
FASC.
A. A drain safety circuit prevents
the heating element from being
energized if the drain valve is
not fully closed. Verify that the
drain valve is fully closed.
B. Call your FASC.