5.4.5 Filter Busy
When FILTER BUSY is displayed (see Figure 36) the
MIB board is waiting on another vat to be filtered or
waiting on a computer error to clear. Wait 30 minutes to
see if problem is corrected. If not, follow the instructions
below.
Do not drain more than one frypot at a time into the built-in filtration unit to avoid
overflow and spillage of hot oil that may cause severe burns, slipping and falling.
The reset switch is used in case the valves did not close
completely. Pressing the reset switch closes all the valves
and resets the system. It takes approximately 60 seconds to
completely reset the filter system.
NOTE: The auto top off feature and the fryer continue to
operate normally during this reset.
The filter pump is equipped with a manual reset switch in case the filter motor
overheats or an electrical fault occurs. If this switch trips, turn off power to the filter
system and allow the pump motor to cool 20 minutes before attempting to reset the
switch (see photo below).
Use caution and wear appropriate safety equipment when resetting the filter pump
reset switch. Resetting the switch must be accomplished with care to avoid the
possibility of a serious burn from careless maneuvering around the drain tube and
frypot.
DANGER
WARNING
WARNING
Filter Pump Reset Switch
5-8