Keep all items out of drains. Closing actuators may cause damage or injury.
5.4
Troubleshooting the Auto Intermittent Filtration (AIF)
5.4.1 Incomplete AIF
Should the AIF procedure fail for any reason after the second filter cycle after the filter pad was
changed - the oil does not completely return to the vat, the drain valve is blocked, an actuator does
not operate, etc - a signal is generated telling the computer that something is wrong.
The computer displays get mgr for ten seconds then
displays enter mgr code (see Figure 10).
1. Enter 1234 (see Figure 11).
Computer displays fill pot from drain pan
(see Figure 12).
With fill
pot
2.
displayed, press the
Figure 13).
Computer displays 15 second countdown timer while the
pump is running (see Figure 14).
Computer displays is pot filled alternating with
yes no (see Figure 15).
(1 yes) if the vat is full (see Figure 16) and
3. Press
skip to section 5.4.2 REMOVE PAN PROMPT. If
the pot is not filled completely continue to next step.
Computer displays is pot filled alternating with
yes no (see Figure 17).
(2 NO) (see Figure 18) if pot is not filled
4. Press
completely.
If NO is chosen, the pump runs for an additional 15
seconds and the computer displays is pot filled
alternating with yes no again.
DANGER
from
drain
pan
(1 yes) to continue (see
5-4
Figure 10
1
2
3
4
Figure 11
Figure 12
Figure 13
Figure 14
Figure 15
Figure 17
(1234)
Figure 16
Figure 18