4.10.4.4 Refilling the Vat from Bulk Oil Systems after Disposal
The computer displays fill pot from bulk
(see Figure 158).
The bulk oil refill pump uses a momentary switch. It only pumps as long as the switch is depressed.
14. Press and hold the
until the oil reaches the fill line (see Figure 159).
15. With the vat full, release the
16. Press the
(2) button, when the vat is full, to close the fill valve (see Figure 160).
The computer displays off (see Figure 161).
4.11 Filter Menu
The filter menu selections are used for filtering, draining, filling and disposing.
4.11.1 Accessing the Filter Menu
Computer displays product or dashed lines (see Figure
162).
1. Press and hold the filter button for the selected vat for
three seconds (see Figure 163).
Computer displays filter menu for three seconds,
changing to Auto Filter (see Figure 164).
2. Press the t and u buttons (see Figure 165) to scroll
between:
a. auto filter
b. maint filter
c. dispose
d. drain to pan
e. fill pot from DRAIN pan
f. fill pot from bulk
(1 yes) button to refill the vat
(1 yes) button.