4.12 Programming Level One
Level one programming is used to enter new products, control when AIF (auto intermittent filtration)
is disallowed, and perform boil out and high-limit tests.
To enter Level 1 programming mode:
1. With the computer OFF, press the TEMP and INFO
buttons simultaneously (see Figure 203) for THREE
seconds until LEVEL 1 is displayed; a chirp sounds
(see Figure 204).
The computer displays ENTER Code and sounds an
alert (see Figure 205).
2. Enter 1234 (see Figure 206).
The computer displays level 1 program for
three seconds (see Figure 207).
The computer then displays Product
selection (see Figure 208).
3. Press the t and ubuttons (see Figure 209) to scroll
between:
a. Product selection
b. aif clock
c. boil out mode
d. high limit test
e. Fryer setup
4. With the desired selection displayed, press the
yes) button to select chosen menu item (see Figure
210).
4.12.1 PRODUCT SELECTION
1. To add or edit products in the product selection mode see pg. 4-14 ADDING A NEW
PRODUCT ITEM TO THE MENU Steps 4-30.
The submenus under product selection are:
1
See pg. 4-29
See pg. 4-30
See pg. 4-32
See pg. 4-35
See pg. 4-9
(1
4-29
Figure 203
Figure 204
Figure 205
2
3
4
(1234)
Figure 206
Figure 207
Figure 208
Figure 209
Figure 210