Keyless Entry Transmitter; Diagnosis And Testing - Keyless Entry; Transmitter; Standard Procedure - Transmitter - Chrysler Concorde 2004 Service Manual

Hide thumbs Also See for Concorde 2004:
Table of Contents

Advertisement

LH
DOOR LOCK SWITCH (Continued)
Fig. 3 DOOR LOCK MOTOR/LATCH
1 - PASSENGER SIDE CONNECTOR
2 - + TO LOCK
3 - DRIVER SIDE CONNECTOR
(2) Carefully separate multiple terminal block on
wiring harness from switch body.
(3) Connect one lead of test light to a ground ter-
minal:
• Touch other test light lead to battery feed B+
terminal.
• If test light comes on, the wiring circuit between
the battery and switch is functional.
• If test light does not come on, check fuse 13 in
the Junction Block for a blown fuse. Refer to Wiring
Diagrams for circuit information.
DOOR LOCK SWITCH
Remove the switch from its mounting location.
Using an ohmmeter, refer to Door Lock Switch Con-
tinuity table to determine if the continuity is correct
in the LOCK and UNLOCK switch positions. If these
results are not obtained, replace the switch.
DOOR LOCK SWITCH CONTINUITY
SWITCH
CONTINUITY
POSITION
BETWEEN
LOCK
1 AND 4
UNLOCK
1 AND 4
KEYLESS ENTRY

TRANSMITTER

DIAGNOSIS AND TESTING - KEYLESS ENTRY

TRANSMITTER
Using special tool 9001, first test to ensure that the
transmitter is functioning. Typical testing distance is
2.5 centimeters (1 inch) for Asian transmitters and
30.5 centimeters (12 inches) for all others. To test,
position the transmitter as shown (Fig. 4). Press any
transmitter button, then test each button individually.
The tool will beep if a radio signal strength that lights
five or more LED's is detected. Repeat this test three
times. If transmitter fails any of the test, refer to the
Diagnostic Procedures manual.

STANDARD PROCEDURE - TRANSMITTER

PROGRAMMING

The Remote Keyless Entry (RKE) Transmitter(s)
can be programmed with the use of the DRB III
scan tool, or by the customer.
PROGRAMMING TRANSMITTER WITH THE DRB
III SCAN TOOL
For procedures on programming the transmitter(s)
with the DRB III scan tool, refer to the proper Body
Diagnostic Procedures Manual.
PROGRAMMING BY CUSTOMER
RESISTANCE
For a customer to be able to program RKE trans-
VALUE
mitters themselves, at least one RKE transmitter
2700
± 10%
must be programmed already. This procedure is to
620
± 10%
add additional transmitters. If all transmitters are
lost, the DRB III scan tool must be used to program
the new transmitter(s).
POWER LOCKS 8N - 5
Fig. 4 RKE TRANSMITTER DIAGNOSIS

Advertisement

Table of Contents
loading

This manual is also suitable for:

300m 2004Intrepid 2004

Table of Contents