Nortel 1000E PRI Installation And Commissioning Manual page 102

Hide thumbs Also See for 1000E PRI:
Table of Contents

Advertisement

102 Configure an E1/T1 card
4
5
6
7
8
9
10
11
12
13
14
Procedure 31
Changing the protocol on an established D-channel using Element manager
Step
1
2
3
4
5
6
Media Gateway 1000E PRI Gateway Installation and Commissioning
Enter the password.
To access LD 22, enter: LD 22
Determine the MSDL which hosts the D-Channel to be changed.
At the prompt, enter: prt
System response: TYPE
Enter: adan dch x
Where x is the D-Channel number
System response: MG_CARD x y z
Where x = loop, y = shelf, z = card
Enter: End
Access LD 96 and enter the command: LD 96
Enter: dis msdl x y z all
Where x, y, and z are the values returned in LD 22
Exit LD 96.
Make the required changed to the D-Channel in LD 17.
Access LD 96 and enter:
enl msdl x y z all
Where x, y, and z are the values returned in LD 22
Action
Log on to Element Manager.
In the sidebar, click on the Routes and Trunks » D-Channels
link.
The D-Channel property page appears.
Click on the EDIT button beside the D-Channel you want to
change.
The property page for the D-channel appears.
Note the Media Gateway Card (MG_CARD) value.
Return to the Routes and Trunks » D-Channels page.
Click the MSDL Diagnostics (LD 96) link.
The MSDL Diagnostics page appears.
Nortel Communication Server 1000
NN43041-311 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
--End--

Advertisement

Table of Contents
loading

Table of Contents