Pri Digital Trunk Loop Configuration - Nortel 1000E PRI Installation And Commissioning Manual

Hide thumbs Also See for 1000E PRI:
Table of Contents

Advertisement

CE-MUX clock controllers
PRI, PRI2, and DPNSS/DASS routes
PRI, PRI2, and DPNSS/DASS trunks
PRI digital trunk loop configuration
Procedure 16 "Configuring PRI loops using LD 17" (page 85)
the configuration in LD 17 to support PRI/T1 loops (common equipment
parameters) on the PRI Gateway.
Procedure 16
Configuring PRI loops using LD 17
Step
1
2
3
Table 16
PRI loop configuration (LD 17)
Prompt
Response
REQ
CHG
TYPE
CEQU
CFN
YES
...
DLOP
loop dd ff
MG_CARD
supl sh card
MODE
PRI
TMDI
NO
...
...
Media Gateway 1000E PRI Gateway Installation and Commissioning
Action
Log on to the CS 1000E.
To access LD 17, enter:
LD 17
Enter the responses shown in
(LD 17)" (page
85).
ATTENTION
VDC configuration is not required for DASS signaling.
Description
Change existing data.
Make changes to common equipment parameters.
Common equipment.
Digital loop (1.5 Mb)
The format is: loop is 0–254, dd is 0-24 (maximum
simultaneous calls) and ff is D2, D3, D4, or ESF.
Enter X to delete the loop.
The physical card for the digital loop association to the
PRI Gateway is required.
The format is: superloop, shelf num, card num. For the
PRI Gateway, card 1-8 is applicable.
Mode of operation.
TMDI functionality is not supported for MGP gateway.
Nortel Communication Server 1000
NN43041-311 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Configure E1/T1 ports on a Call Server 85
Table 16 "PRI loop configuration