Nortel 1000E PRI Installation And Commissioning Manual page 122

Hide thumbs Also See for 1000E PRI:
Table of Contents

Advertisement

122 Configure an E1/T1 card
2
3
Table 33
Parameters for T1 spans
Parameter
Line Code
Frame Mode
Yellow Alarm
LBO
Media Gateway 1000E PRI Gateway Installation and Commissioning
From the Span # list, select the primary span (1 to 8). The span
number must match the MGCLK field defined in LD 17.
For each E1/T1 span, complete these steps:
a For Protocol, select E1 or T1.
b For Usage, select one of the following:
DDCH (PRI D-channel usage attached to the DDCH
daughterboard)
DCHI (DPNSS/DASS D-channel usage attached to the
DCHI daughterboard)
DCHI-SW (DPNSS/DASS D-channel usage attached to
onboard DPNSS/DASS protocols)
BCH (B-channel only)
ATTENTION
You can select DCHI only for E1 spans. The DCHI daughterboard
is allowed only in spans 2, 4, 6, and 8 (corresponding to system
software IPE card slots 2, 4, 6, and 8).
c For each T1 span, configure the parameters as described in
Table 33 "Parameters for T1 spans" (page
ATTENTION
For T1 spans on the E1/T1 card, the following Web interface
parameters are automatically overridden by the Call Server
configuration if a mismatch between the Web interface
configuration and the Call Server configuration exists:
Line Code
Frame Mode
Yellow Alarm
d For each E1 span, configure the parameters as described in
Table 34 "Parameters for E1 spans" (page
Nortel Communication Server 1000
NN43041-311 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Value
B8ZS
ESF
FDL
0–133 FT
122).