128 Maintenance and diagnostics
Step
1
2
3
Table 37
DDCH maintenance commands (LD 96)
Command
DIS DCH x
ENL DCH x (FDL)
EST DCH x
RLS DCH x
RST DCH x
STAT DCH (x)
STAT MON (x)
DIS MSDL sl s c (ALL)
ENL MSDL sl s c (FDL, ALL)
RST MSDL sl s c
STAT MSDL sl s c (FULL)

PRI startup

Use
and DDCH from a disabled state to an operational state.
Procedure 51
Starting up the PRI
Step
1
Media Gateway 1000E PRI Gateway Installation and Commissioning
Action
Log on to the CS 1000E.
To access LD 96, enter:
LD 96
Enter the commands shown in
commands (LD 96)" (page
ATTENTION
In this table, x = the DCH number, and X = the MSDL address (loop
shelf card).
Description
Disable DCH x.
Enable DCH x and attempt to establish the link, and force
download to MSDL.
Establish multiple frame operation on D-channel x.
Release D-channel x.
Reset D-channel x, inhibit signaling.
Get status of one or all D-channels.
Display the incoming and outgoing monitoring status of one or all
D-channels.
Disable DCHI card sl s c.
Enable DCHI card sl s c, with or without Force Download.
Reset MSDL card sl s c.
Get MSDL status sl s c, or a FULL STATUS.
Procedure 51 "Starting up the PRI" (page 128)
Action
Check the status of all PRI/PRI2 cards.
Nortel Communication Server 1000
NN43041-311 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Table 37 "DDCH maintenance
128).
--End--