Inventory Cards; Printing A Pri Gateway Inventory (Ld 117) - Nortel 1000E PRI Installation And Commissioning Manual

Hide thumbs Also See for 1000E PRI:
Table of Contents

Advertisement

3
4
5

Inventory cards

Printing a PRI Gateway inventory (LD 117)

All installed PRI Gateways are included in the output of the Inventory
feature when executed for cards or for all devices.
To print the inventory card for the PRI Gateway, enter:
inv prt cards
The card inventory prints out as shown in this example:
...
PRI, 262, NTDW70AAE5 01 NNTML2????????????
Media Gateway 1000E PRI Gateway Installation and Commissioning
The example in
Figure 38 "IDA status check" (page 135)
that the upper-left DCHI (associated with span 2) is enabled.
Figure 38
IDA status check
To check the status of PRIs, enter:
LD 75
STAT DDCS n
To check the status of all DCHI ports, enter:
LD 75
STAT DDSL (n)
The response for the DCHI status is:
ENBL ACTIVE
DCHI is enabled and all configured channels are normally
enabled.
Check that the PRI cables are connected to the E1/T1 span
connectors.
Nortel Communication Server 1000
NN43041-311 04.01 4 June 2010
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Inventory cards 135
--End--