Acknowledge Requests And Replies - Printronix S828 Programmer's Manual

Table of Contents

Advertisement

Programmer Manual 
Data is an optional field and is not present for all commands. This field contains specific subcommands,
parameters, and data appropriate for the given command. The length of the data field can range from 0 to
32760 (X'7FF8') if the correlation ID is present. If the correlation ID is not present, the length of the data
field can range from 0 to 32762 (X'7FFA').
Table 3. Valid IPDS Command Codes for the Printronix S828 IPDS Printer
Command
Hex Code
SHS
D697
STM
D6E4
NOP
D603
LSS
D61E
XOH
D68F
XOA
D633
BP
D6AF
EP
D6BF
LCC
D69F
LPD
D6CF
LPP
D66D
WBCC
D680
WBC
D681
WGC
D684
WG
D685
WIC
D63D
WI
D64D
WT
D62D
BO
D6DF
DO
D6EF
IO
D67D
BPS
D65F
DPS
D66F
IPS
D67F
LE
D61D
LFE
D63F
DF
D64F
END
D65D

Acknowledge Requests and Replies

The following sections explain:
● Acknowledge Reply (ACK)
● Host Acknowledgment Requests
● Printer Acknowledgement Replies
Chapter 4 IPDS Commands 
Description
Set Home State
Sense Type and Model
No Operation
Load Symbol Set
Execute Order Home State
Execute Order Any State
Begin Page
End Page
Load Copy Control
Logical Page Descriptor
Logical Page Position
Write Bar Code Control
Write Bar Code
Write Graphics Control
Write Graphics
Write Image Control
Write Image
Write Text
Begin Overlay
Deactivate Overlay
Include Overlay
Begin Page Segment
Deactivate Page Segment
Include Page Segment
Load Equivalence
Load Font Equivalence
Deactivate Font
End