Printronix S828 Programmer's Manual page 229

Table of Contents

Advertisement

Programmer Manual 
X'029101' BO Overlay Number Already Loaded
Explanation: The host attempted to download an
overlay from the Begin Overlay command that
already exists in the printer.
Alternate Exception Action: None.
X'029201' Overlay Number Not Loaded
Explanation: The overlay identified by the Overlay
Identifier on the Include Overlay, Deactivate Overlay
or LCC command was not loaded or was already
deleted prior to its attempted use.
Alternate Exception Action: None.
X'029301' Recursive Overlay Invocation:
Explanation: An infinite nesting loop has occurred
with the Include Overlay command (for example, an
overlay has included itself).
Alternate Exception Action: None.
X'029501'
Page
Segment
Loaded
Explanation: The host attempted to download a
page segment that already exists in the printer.
Alternate Exception Action: None.
X'029701' Overlay Nesting Limit Exceeded
Explanation: Depth of overlay nesting is greater
than the maximum depth.
Alternate Exception Action: None.
 
 
 
Chapter 6 IPDS Exception Reporting Codes 
 
Number
Already
227 
X'029102' Invalid Request Resource List
Parameter
Explanation:
1. The Requested Ordering parameter of a
Request Resource List order is not a valid or
supported value.
2. The Entry Index parameter of a Request
Resource List order is not a valid or supported
value.
3. The Resource Qualifier parameter of a
Request Resource List order is not a valid or
supported value.
4. The Resource Type parameter on the
Request Resource List order is not a valid or
supported value.
Alternate Exception Action: None.
X'029202'
Invalid
Parameter:
The
Explanation:
parameter is X'00', which is a reserved value.
Alternate Exception Action: None.
X'029401' Recursive Overlay Invocation:
Explanation:
1. The Page Segment Identifier on the Include
Page Segment command is not a valid or
supported value.
2. The Page Segment Identifier on the Begin
Page Segment command is not a valid or
supported value.
Alternate Exception Action: None.
X'029601'
Page
Segment
Loaded
Explanation: The page segment identified by
the Page Segment Identifier on the Include
Page Segment or Deactivate Page Segment
command was not loaded or was already
deleted prior to its attempted use.
Alternate Exception Action: None.
X'029801'
Suppression
Valid Range
Explanation:
1. On a Write Text command, the Begin
Suppression number value is not a valid or
supported value.
2. In a LCC command, the suppression number
value is not a valid or supported value.
Alternate Exception Action:
1. Ignore the control sequence.
2. None.
PTX‐S828 
Print
Quality
Control
Print
Quality
Control
Number
Not
Number
Outside
260071‐001A 

Advertisement

Table of Contents
loading

Table of Contents