Figure 15. Exception Handling Control (Part 3 of 3)

Print Quality Control (PQC)
The Print Quality Control subcommand allows the host to specify the desired print quality without changing
fonts (see notes). The quality selection (from the PQC subcommand) specifies the quality for printing text
associated with fonts selected by the Set Coded Font Local (SCFL) command and defined by the Load
Font Equivalence (LFE) command. A PQC specifying a print quality compatible with the desired font
should precede the SCFL command. The PQC has no effect when the default font (defined by the offline
operator panel selection) is in use.
The following bytes contain the print quality selection, as shown:
Byte
Value
Bit 0-1 F800
Bit 2
00
01 - 55
56 - AA
AB - FE
FF
Note: Host Fast Draft disabled.
Chapter 5 IPDS Programming Information 
Description
PQC Order Code
Reserved
DP
DP Text
NLQ
Depends on Operator Panel setting
 