Printronix S828 Programmer's Manual page 219

Table of Contents

Advertisement

Programmer Manual 
Alternate Exception Action: None.
X'040500' Bar Code Color Requested Is Not
Supported
The color requested in the Write Bar
Explanation:
Code Data Descriptor field is not supported.
Alternate Exception Action: Use printer default
color.
X'040600' Bar Code Color Requested Is Not
Supported
Explanation: The unit/module width specified in the
Write Bar Code Data Descriptor field is not
supported.
Alternate Exception Action: Use closest smaller
width supported or the device default for those
devices with only one fixed default value.
X'040800' Height Multiplier Specified Is Not
Supported
Explanation: The height multiplier specified in the
Write Bar Code Data Descriptor field is not
supported.
Alternate Exception Action: Use closest multiplier
supported.
X'040A00' Invalid Symbol Reference Point
Explanation: The symbol reference point given in
the Write Bar Code command is not a valid or
supported value.
Alternate Exception Action: None.
X'040C00' Invalid Bar Code Data Length
Explanation: The length of the variable data (as
given in bytes 5-n of the Write Bar Code command)
to be bar-encoded/printed, plus any printer-generated
check digits to be coded/printed, is not a valid or
supported value.
Alternate Exception Action: None.
X'041000' HRI Location Not Supported
Explanation: HRI location specified in the FLAGS
byte of the WBC command is not a supported
location.
Alternate Exception Action: None.
Chapter 6 IPDS Exception Reporting Codes 
 
Alternate Exception Action: Use printer
default.
X'040700' Element Height Specified Is Not
Supported
Explanation: The element height specified in
the Write Bar Code Data Descriptor field is not
supported.
Alternate Exception Action: Use closest
height supported
X'040900'
Wide/Narrow
Supported
Explanation: The wide/narrow ratio specified
in the Write Bar Code Data Descriptor field is
not supported.
Alternate Exception Action: Use the printer
default wide element width. The default wide
element width and the specified or default
unit/module width should be such that a
wide/narrow ratio of 2.50 or 3.00 results.
X'040B00' Invalid Bar Code Modifier
Explanation: The bar code modifier, byte 17
of the Bar Code Data Descriptor structured
field, is not a valid or supported value for the
bar code type specified by byte 16 of the same
structured field.
Alternate Exception Action: None.
X'040E00' Check Digit Calculation Error
Explanation: A first check digit calculation
resulting in a value of 10 is defined as an error
in various modifier options (byte 17 of the Bar
Code Data Descriptor structured field) for the
MSI bar code.
Alternate Exception Action: None.
X'041100' Attempt to Print Portion of
Symbol Outside Block or VPA
Explanation:
1. A portion of the bar code presentation
space, as mapped into the block, extends
outside the bar code block boundaries, or a
portion of the bar code block extends outside
of the logical page (or current overlay).
2. An attempt is made to print a bar code
symbol or HRI outside the physical page.
3. The symbol reference point lies outside the
bar code block, presentation space, or logical
page (or current overlay).
Alternate Exception Action: None.
217 
PTX‐S828 
Ratio
Is
Not
260071‐001A 

Advertisement

Table of Contents
loading

Table of Contents