Transparent communication sample program
- Program contents
In this sample program, the ET-LAN has been installed in Slot No. 0
-
In this program, the contents of the transmission buffer (1K words) for Connection 1 are sent to the
-
transmission side and received on the reception side using the transparent communication.
When the auto connection function is available, use the setup tool (Configurator ET) to perform the
-
initialization information settings and the connection information settings for both transmission and
reception sides which are required for the open processing. The setting descriptions are as shown
below.
- Setting using the setup tool (Configurator ET)
(Transmission side)
Classification
of processing
Initialization
Initialization
processing
information
setting
Open
Connection
processing
setting
(Reception side)
Classification
of processing
Initialization
Initialization
processing
information
setting
Open
Connection
processing
setting
10-20
Setting item
Internal relay allocation
Initialization processing
Open processing
Data transfer
Setting item
Source
Source node IP address
node
Communication function setting between networks
setting
Source node MEWTOCOL station No.
Time setting
Transparent communication setting
Connection
Open method
information
setting
Source node port No.
Destination node IP address
Destination node port No.
Destination node MEWTOCOL station No.
Connection closing time
Number of re-open times
Setting item
Source
Source node IP address
node
Communication function setting between networks
setting
Source node MEWTOCOL station No.
Time setting
Transparent communication setting
Connection
Open method
information
setting
Source node port No.
Destination node IP address
Destination node port No.
Destination node MEWTOCOL station No.
Connection closing time
Number of re-open times
Setting method
Ladder program
Configurator ET
Configurator ET
Ladder program
Description
192.168.1.1
Not used
1
Default
Default
Transparent
communication
TCP/IP:
Active Open
8000
192.168.1.2
(C0A80102H)
8000
5
1
255
Description
192.168.1.2
Not used
5
Default
Default
Transparent
communication
TCP/IP:
Unpassive
Open
8000
192.168.1.1
(C0A80102H)
8000
1
1
255