Genie GS-2669 DC Service And Repair Manual page 97

Serial number range from gs6912-1300/from gs6916f-7897 to gs6916f-10499/from gs69f-10500
Hide thumbs Also See for GS-2669 DC:
Table of Contents

Advertisement

Service and Repair Manual
Outrigger Components
8
Use the Scroll Up or Scroll Down buttons to
scroll to Outriggers.
9
Press the Enter button to select Outriggers.
10 Use the Scroll Up or Scroll Down buttons to
scroll to Calibrate Outriggers.
11 Press the Enter button to select Calibrate
Outriggers.
12 Press and hold the Enter button while the
system gathers data to calibrate the outrigger
level sensor.
Crushing hazard. Keep body
parts away from outriggers
during outrigger movement.
13 Continue holding the Enter button after the
outrigger level sensor is calibrated. The
outriggers will retract while the outrigger
system gathers and saves data.
14 Continue holding the Enter button after the
outriggers retract. The outriggers will now
extend and the system will gather and save
data to calibrate the outriggers.
15 Continue holding the Enter button after the
outriggers extend. The outriggers will now
retract while the outrigger system gathers and
saves data.
Result: The alarms at the ground and platform
controls should sound for 1 second. The
outrigger system is calibrated.
Note: After installing a new outrigger level sensor,
the new outrigger level sensor must be calibrated
following this procedure.
86
GS-2669 DC • GS-3369 DC • GS-4069 DC
November 2016
Part No. 1272220GT