November 2016
5
Install the new level sensor onto the machine
with the "X" on the level sensor base towards
the steer end of the machine. Install and
tighten the level sensor retaining fasteners.
Tip-over hazard. The tilt level
sensor must be installed with the
"X" on the level sensor base
towards the steer end of the
machine. Failure to install the tilt
level sensor as instructed could
result in the machine tipping over
causing death or serious injury.
1 chassis
2 level sensor
3 "Y" indicator
4 "X" indicator
Part No. 1272220GT
GS-2669 DC • GS-3369 DC • GS-4069 DC
Ground Controls
6
Connect the wire harness to the level sensor.
7
Adjust the level sensor retaining fasteners
until the bubble in the top of the level sensor is
centered in the circles.
Note: Be sure there are threads showing through
the top of the adjusting fasteners.
8
Calibrate the new level sensor. Refer to
Repair Procedure,
the Level Sensor
.
Service and Repair Manual
How to Install and Calibrate
39