Fault Codes
Type "PXXX" Faults, continued
DTC
Message on
Number
GCON LCD
P032
P032:COILFAULT
BRAKE/LC LR:Bat+
P035
P035:COILFAULT
BRAKE RR:Bat-
P036
P036:COILFAULT
BRAKE LR:Bat-
P037
P037:BATTERY
OUT OF RANGE
P038
P038:DEVICEFAULT
BAT BALANCER
P039
P039:DEVICEFAULT
BRAKE PWR RELAY
P040
P040:COILFAULT
BRAKE PWR OPEN
106
Description
Short or open circuit of the left rear
brake coil circuit.
Short circuit of the right rear coil
circuit (B5) to battery negative.
Brake circuit miswired.
Short circuit of the left rear brake coil
circuit (B5) to battery negative.
Brake circuit miswired.
Battery voltage is out of range at
startup.
Battery pack out of balance.
Short or open circuit of the brake
relay contact or coil.
Short or open circuit of the brake
relay contact or coil to battery
negative.
GS-2669 DC • GS-3369 DC • GS-4069 DC
Possible Causes
• Short or open circuit in left rear brake harness.
• Short or open circuit in left rear brake coil.
• Left rear DCON ECM.
• Short circuit in right rear brake harness.
• Short circuit in right rear brake coil.
• Right rear brake harness miswired.
• Right rear DCON ECM.
• Short circuit in left rear brake harness.
• Short circuit in left rear brake coil.
• Left rear brake harness miswired.
• Left rear DCON ECM.
• Short or open circuit in voltage sensor circuits.
• Low batteries.
• Faulty battery.
• Battery charger connected to AC power source.
• Left or right DCON ECM.
• Short or open circuit in voltage sensor circuits.
• Faulty battery balancer.
• Faulty battery.
• Battery terminal corrosion.
• Loose battery terminal.
• GCON ECM.
• Short or open circuit in brake relay harness.
• Brake relay contact stuck closed.
• Faulty brake relay.
• GCON ECM.
• Short or open circuit in brake relay harness.
• Faulty brake relay.
• Left or right DCON ECM.
• GCON ECM.
November 2016
Failure Mode
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions inhibited.
All functions operate.
All functions inhibited.
All functions inhibited.
Part No. 1272220GT